电流传感器
| 图片 | 制造商料号 | 库存情况 | 数量 | 数据手册 | 系列 | 封装/外壳 | 包装 | 产品状态 | 用于测量 | 传感器类型 | 电流 - 传感 | 通道数 | 输出 | 灵敏度 | 频率 | 线性度 | 精度 | 电压 - 电源 | 响应时间 | 电流 - 电源(最大值) | 工作温度 | 等级 | 认证 | 极化 | 安装类型 | 供应商设备封装 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CRD4170-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4170-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4170-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 3 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LT 1005-T/SP39TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MGS-1800-15003PH 18" COILS 1500A:4-20MA |
1 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 1500A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
LT 2005-TTRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | 0°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CD 100-S/SP8TRANSDUCER |
0 |
|
|
CD | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Voltage | - | DC ~ 11Hz | - | ±3% | 15V | - | 60mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DV 4200/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 4000/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 2800/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 4200/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DV 3000/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ISOBLOCK I-ST-1C (50A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 50A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
HAZ 12000-SBTRANSDUCER |
0 |
|
|
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 12000-SBITRANSDUCER |
0 |
|
|
HAZ | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 12000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | 15V | 10µs | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 2005-S/SP24TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±12V ~ 15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP37TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP43TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP27TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP44TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
分类概览
电流传感器 产品与选型指南
电流传感器 广泛应用于工业控制、汽车电子、通信设备、消费电子、新能源及其他电子系统。我们提供多品牌、多封装及不同规格的相关产品,方便工程师、采购人员和研发团队进行型号筛选、参数比较和采购询价。
您可以根据制造商、关键参数、库存情况及 Datasheet 信息筛选适合的 电流传感器。如暂时没有找到完全匹配的型号,也可以提交询价,我们将协助确认库存、交期以及可替代型号。
FAQ
如何选择合适的 电流传感器?
建议先确认电气参数、封装、工作温度、应用环境以及品牌要求,再结合库存和交期进行筛选。
页面上的库存信息是否可以直接采购?
库存会随供应情况变化。对于项目采购或批量需求,建议提交询价,以便进一步确认实时库存、价格和交期。
找不到指定型号怎么办?
您可以提交型号和数量需求,我们可以协助查询缺货型号,并根据参数提供可替代型号建议。
是否可以提供 Datasheet 和技术资料?
可以。产品列表中的 Datasheet 链接可用于查看相关技术资料;如资料暂缺,也可以联系我们协助查找。