| 图片 | 制造商料号 | 库存情况 | 数量 | 数据手册 | 系列 | 封装/外壳 | 包装 | 产品状态 | 用于测量 | 传感器类型 | 电流 - 传感 | 通道数 | 输出 | 灵敏度 | 频率 | 线性度 | 精度 | 电压 - 电源 | 响应时间 | 电流 - 电源(最大值) | 工作温度 | 等级 | 认证 | 极化 | 安装类型 | 供应商设备封装 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK I-ZF (300AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 300A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (50A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 50A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (300A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 300A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (200A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 200A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (150AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 150A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (10A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Obsolete | DC | Current Transducer | 10A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (100AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
|
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 100A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
CR4320-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
1698172SENSOR CURRENT HALL 55A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Current Transducer | 50A | 1 | Analog Voltage | - | DC, 10Hz ~ 1kHz | - | - | 9.6V ~ 30V | 200ms | - | -40°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
CR4320-50SENSOR CURRENT XFMR 50A AC |
0 |
|
|
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CTR20000SENSOR CURRENT 100A, 150A, 200A |
0 |
|
|
CTR | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±0.8% | 24V | 600ms | 23mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4320-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
HAZ 10000-SBSENSOR CURRENT HALL AC/DC 10000A |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect | 10000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | 15V | - | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 2000-SB/SP1SENSOR CURRENT HALL 2000A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC ~ 4kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD5150-XXX-XX-MCRD5150-XXX-XX-M |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AKR 2000 C420L JTRANSDUCER |
0 |
|
|
AKR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2000A | 1 | Analog Voltage | - | 10Hz ~ 400Hz | - | ±1% | 24V | 600ms | - | -20°C ~ 50°C | - | - | - | Chassis Mount | - |
|
CTL0052SSENSOR CURRENT XFMR 2A, 5A AC |
0 |
|
|
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 2A, 5A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
LV 100-2000/SP11SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4160-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4100 | Module, Dual Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 70mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
2814647SENSOR CURRENT HALL 55A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
分类概览
电流传感器 产品与选型指南
电流传感器 广泛应用于工业控制、汽车电子、通信设备、消费电子、新能源及其他电子系统。我们提供多品牌、多封装及不同规格的相关产品,方便工程师、采购人员和研发团队进行型号筛选、参数比较和采购询价。
您可以根据制造商、关键参数、库存情况及 Datasheet 信息筛选适合的 电流传感器。如暂时没有找到完全匹配的型号,也可以提交询价,我们将协助确认库存、交期以及可替代型号。
FAQ
如何选择合适的 电流传感器?
建议先确认电气参数、封装、工作温度、应用环境以及品牌要求,再结合库存和交期进行筛选。
页面上的库存信息是否可以直接采购?
库存会随供应情况变化。对于项目采购或批量需求,建议提交询价,以便进一步确认实时库存、价格和交期。
找不到指定型号怎么办?
您可以提交型号和数量需求,我们可以协助查询缺货型号,并根据参数提供可替代型号建议。
是否可以提供 Datasheet 和技术资料?
可以。产品列表中的 Datasheet 链接可用于查看相关技术资料;如资料暂缺,也可以联系我们协助查找。