电流传感器
| 图片 | 制造商料号 | 库存情况 | 数量 | 数据手册 | 系列 | 封装/外壳 | 包装 | 产品状态 | 用于测量 | 传感器类型 | 电流 - 传感 | 通道数 | 输出 | 灵敏度 | 频率 | 线性度 | 精度 | 电压 - 电源 | 响应时间 | 电流 - 电源(最大值) | 工作温度 | 等级 | 认证 | 极化 | 安装类型 | 供应商设备封装 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
5AS-2500A:5A-1.5x6.5(1%,2.5VA)1.5x6.5" SPLIT-CORE 2500A:5A 1%2 |
2 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 2500A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-1600A:5A-4x6(0.5%,2.5VA)4x6" SPLIT-CORE 1600A:5A 0.5%2.5 |
2 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 1600A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-1200A:5A-4x6(0.5%,2.5VA)4x6" SPLIT-CORE 1200A:5A 0.5%2.5 |
2 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 1200A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-600A:5A-2.75 (0.2%,IP68)2.75" SPLIT-CORE 600A:5A 0.2%IP6 |
2 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 600A | 1 | Ratiometric, 5A | - | - | - | ±0.2% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-2000A:5A-5x5(0.5%,2.5VA)5" SPLIT-CORE 2000A:5A 0.5%2.5VA |
6 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 2000A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
ASX-NOAC-FTCurrent Switch AC, Adj. 1.5-175 |
5 |
|
|
ASX | Module, Single Pass Through | Bulk | Active | AC/DC | Current Switch | 12A, 55A, 175A (Selectable) | 1 | Relay, NO | - | DC, 50Hz ~ 100Hz | - | - | - | 15s | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
5AS-2500A:5A-5X5(0.5%,2.5VA)5" SPLIT-CORE 2500A:5A 0.5%2.5VA |
3 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 2500A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-1000A:5A-5x5(0.5%,2.5VA)5" SPLIT-CORE 1000A:5A-5x5 0.5%2 |
3 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 1000A | 1 | Ratiometric, 1A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-2000A:5A-5x7(1%,2.5VA)5x7" SPLIT-CORE 2000A:5A 1%2.5VA |
14 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 2000A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-2500A:5A-5x7(0.5%,2.5VA)5x7" SPLIT-CORE 2500A:5A 0.5%2.5 |
9 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 2500A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3000A:5A-5x7(1%,2.5VA)5x7" SPLIT-CORE 3000A:5A 1%2.5VA |
7 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3000A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3000A:5A-5x7(2.5VA)5x7" SPLIT-CORE 3000A:5A 2.5VA |
5 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3000A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-4000A:5A-5X7(2.5VA)5x7" SPLIT-CORE 4000A:5A 2.5VA |
3 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 4000A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
ASR-400MV-11/GHIGH INPUT ROGOWSKI COIL 11" DIA |
23 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 50000A | 1 | Ratiometric, Current | - | 40Hz ~ 14kHz | ±0.2% | ±0.5% | Self Powered | - | - | -30°C ~ 80°C | - | - | - | Free Hanging | - |
|
5AS-3000A:5A-6x3(0.5%,5VA)6x3" SPLIT-CORE 3000A:5A 0.5%5VA |
19 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3000A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-4000A:5A-6x6(0.5%,2.5VA)6x6" SPLIT-CORE 4000A:5A 0.5%2.5 |
14 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 4000A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3500A:5A-2.5x4.5(2.5VA)2.5x4.5" SPLIT-CORE 3500A:5A 2.5 |
6 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3500A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3000A:5A-6x6(0.5%,2.5VA)6x6" SPLIT-CORE 3000A:5A 0.5%2.5 |
5 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3000A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3500A:5A-6x6(0.5%,2.5VA)6x6" SPLIT-CORE 3500A:5A 0.5%2.5 |
3 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3500A | 1 | Ratiometric, 5A | - | - | - | ±0.5% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
|
5AS-3500A:5A-5x7(2.5VA)5x7" SPLIT-CORE 3500A:5A 2.5VA |
3 |
|
|
5AS | - | Case | Active | AC | Current Sensor | 3500A | 1 | Ratiometric, 5A | - | - | - | ±1% | - | - | - | -40°C ~ 70°C | - | - | - | Free Hanging | - |
分类概览
电流传感器 产品与选型指南
电流传感器 广泛应用于工业控制、汽车电子、通信设备、消费电子、新能源及其他电子系统。我们提供多品牌、多封装及不同规格的相关产品,方便工程师、采购人员和研发团队进行型号筛选、参数比较和采购询价。
您可以根据制造商、关键参数、库存情况及 Datasheet 信息筛选适合的 电流传感器。如暂时没有找到完全匹配的型号,也可以提交询价,我们将协助确认库存、交期以及可替代型号。
FAQ
如何选择合适的 电流传感器?
建议先确认电气参数、封装、工作温度、应用环境以及品牌要求,再结合库存和交期进行筛选。
页面上的库存信息是否可以直接采购?
库存会随供应情况变化。对于项目采购或批量需求,建议提交询价,以便进一步确认实时库存、价格和交期。
找不到指定型号怎么办?
您可以提交型号和数量需求,我们可以协助查询缺货型号,并根据参数提供可替代型号建议。
是否可以提供 Datasheet 和技术资料?
可以。产品列表中的 Datasheet 链接可用于查看相关技术资料;如资料暂缺,也可以联系我们协助查找。