| 图片 | 制造商料号 | 库存情况 | 数量 | 数据手册 | 系列 | 封装/外壳 | 包装 | 产品状态 | 用于测量 | 传感器类型 | 电流 - 传感 | 通道数 | 输出 | 灵敏度 | 频率 | 线性度 | 精度 | 电压 - 电源 | 响应时间 | 电流 - 电源(最大值) | 工作温度 | 等级 | 认证 | 极化 | 安装类型 | 供应商设备封装 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
ACS758LCB-100B-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,680 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS758ECB-200U-PFF-TSENSOR CURRENT HALL 200A 5-CB |
1,668 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±1.2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 85°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-100U-PFF-TSENSOR CURRENT HALL 100A 5-CB |
1,265 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.25% | ±2.4% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS758LCB-050U-PFF-TSENSOR CURRENT HALL 50A 5-CB |
1,162 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 60mV/A | DC ~ 120kHz | ±1% | ±2% | 3V ~ 5.5V | 4µs | 13.5mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS756KCB-050B-PFF-TSENSOR CURRENT HALL |
189 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1.8% | ±7.5% | 3V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100U-PFF-TSENSOR CURRENT HALL 100A DC |
11,890 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
11,486 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS759ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
5,393 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 6.6mV/A | DC ~ 120kHz | ±1% | ±4% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150B-PFF-TSENSOR CURRENT HALL 150A AC/DC |
4,043 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 13.3mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200B-PFF-TSENSOR CURRENT HALL 200A AC/DC |
3,135 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-100B-PFF-TSENSOR CURRENT HALL 100A AC/DC |
2,336 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770KCB-150U-PFF-TSENSOR CURRENT HALL 150A DC |
2,022 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | 26.7mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS770ECB-200U-PFF-TSENSOR CURRENT HALL 200A DC |
1,657 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
|
ACS759LCB-050B-PFF-TSENSOR CURRENT HALL 50A AC/DC |
748 |
|
|
- | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 26.4mV/A | DC ~ 120kHz | ±1% | ±3.5% | 3V ~ 3.6V | 4µs | 13.5mA | -40°C ~ 150°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
|
ACS770LCB-050U-PFF-TSENSOR CURRENT HALL 50A DC |
690 |
|
|
ACS770 | 5-CB Formed Leads, PFF | Tube | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 80mV/A | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 150°C | - | - | Unidirectional | Through Hole | 5-CB Module |
|
T60404N4646X651CURRENT SENSOR, 25A, 3 PRI PINS, |
1,765 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
HXS 20-NPSENSOR CURRENT HALL 5A, 10A, 20A |
1,578 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A, 10A, 20A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HXS 50-NPSENSOR CURRENT 12.5A, 25A, 50A |
399 |
|
|
HXS | Module | Tube | Not For New Designs | AC/DC | Hall Effect, Open Loop | 12.5A, 25A, 50A (Selectable) | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 6-PSENSOR CURRENT HALL 6A AC/DC |
283 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1.4% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X412CURRENT SENSOR, 100A, 3 PRI PINS |
1,357 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 50A, 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500ns | 18.5mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
分类概览
电流传感器 产品与选型指南
电流传感器 广泛应用于工业控制、汽车电子、通信设备、消费电子、新能源及其他电子系统。我们提供多品牌、多封装及不同规格的相关产品,方便工程师、采购人员和研发团队进行型号筛选、参数比较和采购询价。
您可以根据制造商、关键参数、库存情况及 Datasheet 信息筛选适合的 电流传感器。如暂时没有找到完全匹配的型号,也可以提交询价,我们将协助确认库存、交期以及可替代型号。
FAQ
如何选择合适的 电流传感器?
建议先确认电气参数、封装、工作温度、应用环境以及品牌要求,再结合库存和交期进行筛选。
页面上的库存信息是否可以直接采购?
库存会随供应情况变化。对于项目采购或批量需求,建议提交询价,以便进一步确认实时库存、价格和交期。
找不到指定型号怎么办?
您可以提交型号和数量需求,我们可以协助查询缺货型号,并根据参数提供可替代型号建议。
是否可以提供 Datasheet 和技术资料?
可以。产品列表中的 Datasheet 链接可用于查看相关技术资料;如资料暂缺,也可以联系我们协助查找。